Dodge Sprinter 2006 Manual page 2141

Hide thumbs Also See for Sprinter 2006:
Table of Contents

Advertisement

VA
1 - FUEL LINE
2 - RETAINING CLAMP
(3) Rem ove cla m p fr om t h e fu el lin e a t t h e fu el
t a n k con n ect ion a n d sepa r a t e t h e lin e fr om t h e t a n k.
(4) Rem ove a n y r et a in in g clips a n d r em ove t h e
fu el lin e fr om veh icle.
INSTALLA TION
WARNING: Do not operate the diesel supplemental
cabin heater in an enclosed area such as a garage
that does not have exhaust ventilation facilities.
Always vent the cabin heater exhaust when operat-
ing the cabin heater. Allow the diesel supplemental
cabin heater to cool before performing any service
procedures to the cabin heater. Verify that all diesel
supplemental cabin heater fuel lines are securely
fastened to their respective components before per-
forming any service procedures to the cabin heater.
Failure to follow these warnings may result in pos-
sible personal injury or death.
NOTE: Verify that there is more than 1/8 of a tank of
fuel in the vehicle's fuel tank before performing this
procedure. Add fuel, if necessary.
(1) In st a ll t h e ca bin h ea t er fu el su pply lin e in t o
veh icle a n d fu el lin e r et a in er s.
(2) In st a ll t h e fu el lin e con n ect ion a t t h e fu el t a n k
a n d t igh t en t h e con n ect ion secu r ely.
Fig. 3 Cabin Heater Dosing Pump Fuel Line
3 - DOSING PUMP
4 - HEATER AIR INTAKE PIPE
(3) In st a ll t h e fu el lin e a t t h e dosin g pu m p a n d
t igh t en t h e con n ect ion secu r ely.
(4) Lower t h e veh icle.
NOTE: Failure to prime the dosing pump after drain-
ing the supplemental cabin fuel line will prevent
cabin heater activation during the first attempt to
start the cabin heater. This will also set a diagnostic
trouble code (DTC) in the cabin heater control's
memory. Do not perform the Dosing Pump Priming
procedure if an attempt was made to start the cabin
heater without priming the dosing pump first. This
will put excess fuel in the cabin heater and cause
smoke to emit from the cabin heater exhaust pipe
when cabin heater activation occurs.
(5) Con n ect t h e DRBIII
t ic lin k con n ect or.
(6) Tu r n t h e ign it ion t o t h e ON posit ion .
NOTE: Do not activate the dosing pump prime more
than one time. This will put excess fuel in the sup-
plemental cabin heater and cause smoke to emit
from the cabin heater exhaust pipe when cabin
heater activation occurs.
NOTE: A clicking noise heard coming from the dos-
ing pump indicates that the pump is operational.
CABIN HEA TER 24 - 109
sca n t ool t o t h e dia gn os-

Hide quick links:

Advertisement

Chapters

Table of Contents

Troubleshooting

loading

Table of Contents