Connecting Sensors/Actuators
7.2 Connecting I/O via PROFIsafe
7.2.4

Parameterizing the F master (NCK)

The F master is parameterized in the machine data of the NCK and comprises the
following subareas:
S PROFIsafe communication
– PROFIsafe address of the F master
– PROFIsafe clock cycle
See Chapter 7.2.5 "Configuring and parameterizing the PROFIsafe I/O"
S SPL–SGE/SGA interface
– PROFIsafe address of the F module
– F net data filter
– SGE/SGA assignment
SPL–SGE interface See Chapter 7.2.6 "Parameterizing the SPL–SGE interface
(NCK)".
SPL–SGA interface: See Chapter 7.2.7 "Parameterizing the SPL–SGA inter-
face (NCK)".
7.2.5

Parameterizing the PROFIsafe communication (NCK)

F master address
In order to define a unique and clear communication relationship between F slave
and F master, in addition to the target address (PROFIsafe address of the F
slave), the source address (PROFIsafe address of the F master) must be defined.
The PROFIsafe address of the F master is entered into the following machine
data:
S MD10385: $MN_PROFISAFE_MASTER_ADDRESS
(PROFIsafe address of the F master)
Input format: 0s 00 aaaa
– s: Bus segment
Range of values: 5 = DP connection on the PLC side
– aaaa: Hexadecimal PROFIsafe address
Range of values: 1...FA7D
Note
The PROFIsafe address of the F master is provided under:
S HW Config > Properties dialog box of the F module > F parameter:
F_source_address
7-208
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) – 05.2008 Edition