05.08
Subsequent alarms for Alarms 27001 and 27101 to 27107
S 27023 STOP B initiated
S 27024 STOP A initiated
Activating
Priorities are assigned to alarms by appropriately parameterizing MD 10094
$MN_SAFE_ALARM_SUPPRESS_LEVEL. When this MD is set to either 12 or 13,
in addition to the alarm suppression, set with values 2 and 3, the function that as-
signs priorities to alarms is also activated.
Alarm 27124
By assigning priorities to alarms, alarms with the power on clear criterion are also
cleared or no longer displayed. In spite of this, the system is in a state in which a
power on is required. If alarm 27024 "Stop A initiated" has occurred, but is no lon-
ger displayed, then at least group alarm 27124 "Stop A for at least 1 axis" is dis-
played.
© Siemens AG 2008 All Rights Reserved
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) – 05.2008 Edition
10.5 Reducing the number of alarms
Diagnostics
10-575