05.08
F01653
Response
Acknowledgement
Explanation
Remedy
F01655
Response
Acknowledgement
Explanation
© Siemens AG 2008 All Rights Reserved
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) – 05.2008 Edition
SI CU: PROFIBUS configuration error
OFF2
IMMEDIATELY (POWER ON)
The PROFIBUS configuration for operating Safety Integrated monitor-
ing functions with a higher–level control (SINUMERIK or F–PLC) is in-
correct.
Note:
This fault results in a STOP A that cannot be acknowledged.
Fault value (r0949, interpret as decimal):
A safety slot has not been configured for the receive data
200:
from the control.
The configured safety slot for the receive data from the con-
210,
trol has an unknown format.
220:
The configured safety slot for the receive data from the
230:
F–PLC has the incorrect length.
The configured safety slot for the receive data from
240:
SINUMERIK has the incorrect length.
A safety slot has not been configured for the send data to the
300:
control.
The configured safety slot for the send data to the control has
310,
an unknown format.
320:
The configured safety slot for the send data to the F–PLC has
330:
the incorrect length.
The configured safety slot for the send data to the
340:
SINUMERIK has the incorrect length.
Check the PROFIBUS configuring of the safety slot on the master side
and, if required, correct.
– Upgrade the Control Unit software.
SI CU: Align the monitoring functions
OFF2
IMMEDIATELY (POWER ON)
An error has occurred when aligning the Safety Integrated monitoring
functions on the Control Unit (CU) and Motor Module (MM). Control
Unit and Motor Module were not able to determine a common set of
supported SI monitoring functions.
– DRIVE–CLiQ communications has an error or failed.
– Safety Integrated software releases on the Control Unit and the
Motor Module are not compatible with one another.
Note:
This fault results in a STOP A that cannot be acknowledged.
Fault value (r0949, interpret as hexadecimal):
Only for internal Siemens troubleshooting.
10.3 Safety messages for SINAMICS S120