05.08
7.3.12
Direct communications between NCK and PLC–SPL
In SPL applications, a certain degree of single–channel communications between
the two SPLs (NCK and PLC) is always required in addition to safety–related
switching elements being connected through two channels. Testing external stops
and the Emergency Stop acknowledgment are typical applications.
In order to be able to exchange single–channel SI–specific signals between the
NCK and PLC in a dedicated data area, a corresponding communication interface
exists between these components. The meaning of the individual bits in this inter-
face are defined by the user.
NCK
$A_PLCSIOUT[1...32]
$A_PLCSIIN[1...32]
Limitations
System variables $A_PLCSIOUT[1...32] and $A_PLCSIIN[1...32] are protected so
that they cannot be accessed from other programs, except the NCK–SPL program
(SAFE.SPF). A corresponding programming command is rejected with the alarm
17070 "Channel %1 block %2 Data write–protected".
© Siemens AG 2008 All Rights Reserved
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) – 05.2008 Edition
7.3 Safe programmable logic (SPL)
PLC
DB18.DBD128
DB18.DBD132
Connecting Sensors/Actuators
32 bits from the NCK to PLC
32 bits from the PLC to NCK