Siemens SINUMERIK 840D sl Function Manual page 466

Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Diagnostics
10.2 NCK safety alarms for SINUMERIK 840D sl
10-466
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) – 05.2008 Edition
36
The setting in MD 36957 $MA_SAFE_PULSE_DIS_CHECK_TIME
does not correspond with the associated drive parameter assignment.
Remedy
Copy SI data.
37
The setting in MD 36952 $MA_SAFE_STOP_SWITCH_TIME_C does
not correspond with the associated drive parameter assignment.
Remedy
Copy SI data.
38
The setting in MD 36953 $MA_SAFE_STOP_SWITCH_TIME_D does
not correspond with the associated drive parameter assignment.
Remedy
Copy SI data.
39
The setting in MD 36954 $MA_SAFE_STOP_SWITCH_TIME_E does
not correspond with the associated drive parameter assignment.
Remedy
Copy SI data.
40
The setting in MD 36961 $MA_SAFE_VELO_STOP_MODE does not
correspond with the associated drive parameter assignment.
Remedy
Copy SI data.
41
The setting in MD 36962 $MA_SAFE_POS_STOP_MODE does not
correspond with the associated drive parameter assignment.
Remedy
Copy SI data.
42
The setting in MD 36960 $MA_SAFE_STANDSTILL_VELO_TOL does
not correspond with the associated drive parameter assignment.
Remedy
Copy SI data.
43
Stop response, memory test.
44 – 57
Explanation
Fault codes 44–57 cannot be clearly assigned to a fault cause. For the
monitoring functions that run internally (e.g. SG), monitoring limits are
internally generated that are referred to a monitoring clock cycle.
Example:
SG1 = 2000 mm/min, monitoring clock cycle = 12 ms
If SG1 is active, then a check is made in every monitoring clock cycle
(MCC) as to whether SG1 was exceeded.