Siemens SINUMERIK 840D sl Function Manual page 520

Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Diagnostics
10.2 NCK safety alarms for SINUMERIK 840D sl
10-520
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) – 05.2008 Edition
The following applies to the "Safe cams" function:
Safe cam 1–: Bits 2, 3 in result list 2
Safe cam 2–: Bits 6, 7 in result list 2
Safe cam 3–: Bits 10,11 in result list 2
Safe cam 4–: Bits 14,15 in result list 2
The following applies to the "Safe cam track" function: (each of the re-
sult lists 3–7 includes 6 cam results)
Safe cam 1–: Bits 2, 3 in result list 3
Safe cam 2–: Bits 6, 7 in result list 3
Safe cam 3–: Bits 10, 11 in result list 3
Safe cam 4–: Bits 14, 15 in result list 3
Safe cam 5–: Bits 18, 19 in result list 3
Safe cam 6–: Bits 22, 23 in result list 3
Safe cam 7–: Bits 2, 3 in result list 4
Safe cam 8–: Bits 6, 7 in result list 4
Safe cam 9–: Bits 10, 11 in result list 4
Safe cam 10–: Bits 14, 15 in result list 4
Safe cam 11–: Bits 18, 19 in result list 4
Safe cam 12–: Bits 22, 23 in result list 4
Safe cam 13–: Bits 2, 3 in result list 5
Safe cam 14–: Bits 6, 7 in result list 5
Safe cam 15–: Bits 10, 11 in result list 5
Safe cam 16–: Bits 14, 15 in result list 5
Safe cam 17–: Bits 18, 19 in result list 5
Safe cam 18–: Bits 22, 23 in result list 5
Safe cam 19–: Bits 2, 3 in result list 6
Safe cam 20–: Bits 6, 7 in result list 6
Safe cam 21–: Bits 10, 11 in result list 6
Safe cam 22–: Bits 14, 15 in result list 6
Safe cam 23–: Bits 18, 19 in result list 6
Safe cam 24–: Bits 22, 23 in result list 6
Safe cam 25–: Bits 2, 3 in result list 7
Safe cam 26–: Bits 6, 7 in result list 7
Safe cam 27–: Bits 10, 11 in result list 7
Safe cam 28–: Bits 14, 15 in result list 7
Safe cam 29–: Bits 18, 19 in result list 7
Safe cam 30–: Bits 22, 23 in result list 7
Monitoring state (%3, %4):
– OFF = monitoring inactive in this monitoring channel
– OK = monitoring active in this monitoring channel, limit values not
violated
– L+ = monitoring active in this monitoring channel, upper limit value
violated