05.08
© Siemens AG 2008 All Rights Reserved
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) – 05.2008 Edition
10.2 NCK safety alarms for SINUMERIK 840D sl
183
Cam position: The setting in MD 36936
$MA_SAFE_CAM_POS_PLUS[27] + $MA_SAFE_CAM_TOL does not
correspond with the associated drive parameter assignment.
Remedy
Safe cam 28+ (+ tolerance). Enter the same MDs.
184
Cam position: The setting in MD 36936
$MA_SAFE_CAM_POS_PLUS[27] does not correspond with the asso-
ciated drive parameter assignment.
Remedy
Safe cam 28+. Enter the same MDs.
185
Cam position: The setting in MD 36937 $MA_SAFE_CAM_POS_
MINUS[27] + $MA_SAFE_CAM_TOL does not correspond with the
associated drive parameter assignment.
Remedy
Safe cam 28– (+ tolerance). Enter the same MDs.
186
Cam position: The setting in MD 36937 $MA_SAFE_CAM_POS_
MINUS[27] does not correspond with the associated drive parameter
assignment.
Remedy
Safe cam 28–. Enter the same MDs.
187
Cam position: The setting in MD 36936
$MA_SAFE_CAM_POS_PLUS[28] + $MA_SAFE_CAM_TOL does not
correspond with the associated drive parameter assignment.
Remedy
Safe cam 29+ (+ tolerance). Enter the same MDs.
188
Cam position: The setting in MD 36936
$MA_SAFE_CAM_POS_PLUS[28] does not correspond with the asso-
ciated drive parameter assignment.
Remedy
Safe cam 29+. Enter the same MDs.
189
Cam position: The setting in MD 36937 $MA_SAFE_CAM_POS_
MINUS[28] + $MA_SAFE_CAM_TOL does not correspond with the
associated drive parameter assignment.
Remedy
Safe cam 29– (+ tolerance). Enter the same MDs.
190
Cam position: The setting in MD 36937 $MA_SAFE_CAM_POS_
MINUS[28] does not correspond with the associated drive parameter
assignment.
Remedy
Safe cam 29–. Enter the same MDs.