05.08
13300
MD number
Default value: 0xFFFFFFFF
Change becomes effective after: POWER ON
Data type: DWORD
Significance:
corresponds with ...
Additional references
© Siemens AG 2008 All Rights Reserved
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) – 05.2008 Edition
$MN_PROFISAFE_IN_FIL TER
F useful (net) data filter IN
Min. input limit: –
Protection level: 7/2
Filter between F net (useful) data and $A_INSE variables
The machine data: $MN_PROFISAFE_IN_FILTER is used to define which F net data bits
of the PROFIsafe module are accepted for further processing from the F net data interface
of the PROFIsafe module in the NCK.
The filtered F net data bits are pushed together inside the NCK to form a bit array without
any gaps (consecutive bit array).
The machine data: $MN_PROFISAFE_IN_ASSIGN is then used to define in which $INSE
variables, the filtered F net data bits are transferred.
Example:
Note: For reasons of simplicity, only 16 bits are taken into consideration.
Parameter assignment:
PROFISAFE_IN_FILTER = 1010100101000100
PROFISAFE_IN_ASSIGN = 011006
n = 16
11
6
1
1010 1000 0000 0100
1010 1001 0100 0100
0000 0000 0011 1001
xxxx x111 001x xxxx
8.1 Machine data for SINUMERIK 840D sl
Max. input limit: –
value at the F net data interface of the
PROFIsafe module
$MN_PROFISAFE_IN_FIL TER
internal NCK F net data image
$INSE[n], x = not relevant
Data Description
Unit: –
8-273