Siemens SINUMERIK 840D sl Function Manual page 121

Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

05.08
v
SGn
vact
SGE "SBH deselection"
SGn is active
Fig. 6-3
Deselecting SBH
Safe operating stop can be deselected using SGE "SBH/SG deselection" (= "1"
signal); this results in a general deactivation of SBH and SG. The SBH function is
also deselected when the SG function is selected using the SGE "SBH deselec-
tion".
Warning
!
The delay time must be selected as a function of the distance to the hazardous
location. The speeds to be taken into account in this respect are stipulated in
Standard DIN EN 999.
Configuring NCK–SGAs
The NCK–SGA "SBH active" is configured using the following machine data:
for 840D sl
MD 36981: $MA_SAFE_SS_STATUS_OUTPUT
Configuring NCK–SGEs
for 840D sl
MD 36971: $MA_SAFE_SS_DISABLE_INPUT
© Siemens AG 2008 All Rights Reserved
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) – 05.2008 Edition
a)
Braking time
Timer running
Timing when SBH is selected from SG
Safety Functions Integrated in the System/Drive
6.2 Safe operating stop (SBH)
a) Braking is initiated
Delay time, speed changeover
SBH is active
t
6-121

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics s120

Table of Contents