Siemens SINUMERIK 840D sl Function Manual page 347

Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

05.08
r9738[0...1]
SI motion, diagnostics result list 6
Displays result list 6 where for a crosswise data comparison with the control,
led to an error.
[0]: Result list second channel
[1]: Result list drive
Bit field
Bit 00
Actual value > Upper limit SN19+
Bit 01
Actual value > Lower limit SN19+
Bit 02
Actual value > Upper limit SN19–
Bit 03
Actual value > Lower limit SN19–
Bit 04
Actual value > Upper limit SN20+
Bit 05
Actual value > Lower limit SN20+
Bit 06
Actual value > Upper limit SN20–
Bit 07
Actual value > Lower limit SN20–
Bit 08
Actual value > Upper limit SN21+
Bit 09
Actual value > Lower limit SN21+
Bit 10
Actual value > Upper limit SN21–
Bit 11
Actual value > Lower limit SN21–
Bit 12
Actual value > Upper limit SN22+
Bit 13
Actual value > Lower limit SN22+
Bit 14
Actual value > Upper limit SN22–
Bit 15
Actual value > Lower limit SN22–
Bit 16
Actual value > Upper limit SN23+
Bit 17
Actual value > Lower limit SN23+
Bit 18
Actual value > Upper limit SN23–
Bit 19
Actual value > Lower limit SN23–
Bit 20
Actual value > Upper limit SN24+
Bit 21
Actual value > Lower limit SN24+
Bit22
Actual value > Upper limit SN24–
Bit23
Actual value > Lower limit SN24–
See also: C01711
Unit:
Default value:
© Siemens AG 2008 All Rights Reserved
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) – 05.2008 Edition
Minimum value:
Maximum value:
Data Description
8.2 Parameters for SINAMICS S120
Checksum:
Yes
Data type:
Unsigned32
Protection level:
3
Effective:
POWER ON
8-347