Siemens SINUMERIK 840D sl Function Manual page 304

Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Data Description
8.1 Machine data for SINUMERIK 840D sl
36982
MD number
Default value: 0
Change becomes effective after: POWER ON
Data type: DWORD
Significance:
Special cases, errors,...
Additional references
36985
MD number
Default value: 0
Change becomes effective after: POWER ON
Data type: DWORD
Significance:
Special cases, errors,...
corresponds with ...
Additional references
36987
MD number
Default value: 0
Change becomes effective after: POWER ON
Data type: DWORD
Significance:
Special cases, errors,...
Additional references
8-304
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) – 05.2008 Edition
$MA_SAFE_VELO_ST ATUS_OUTPUT[n]: 0 ... 1
Output assignment active SG selection
Min. input limit: –
Protection level: 7/2
This machine data defines the outputs or the system variables for the signals "SG active bit
0" and "SG active bit 1".
Configuration: Refer to the coding of the output assignment
n = 1, 0
stands for SG active, bits 1, 0
SG active
Bit 1
Bit 0
means
= 0
= 0
SG1 active, if SBH/SG is active and SBH is not active
SBH active, if SBH/SG are active and SBH is active
= 1
= 0
SG2 active
= 0
= 1
SG3 active
= 1
= 1
SG4 active
If MD bit 31 is set, then the signal is processed inverted.
Refer to MD 36980: $MA_SAFE_SVSS_DISABLE_OUTPUT
$MA_SAFE_VELO_X_ST ATUS_OUTPUT
Output assignment for n < n
x
Min. input limit: –
Protection level: 7/2
This machine data defines the output or the system variable for the signal "n < n
Configuration: Refer to the coding of the output assignment
Signal means
= 0, actual speed is higher than the limit speed in $MA_SAFE_VELO_X
= 1, actual speed is lower or equal to the limit speed
If MD bit 31 is set, then the signal is processed inverted.
MD 36946: $MA_SAFE_VELO_X
Refer to MD 36980: $MA_SAFE_SVSS_DISABLE_OUTPUT
$MA_SAFE_REFP_ST ATUS_OUTPUT
Output assignment, axis safely referenced
Min. input limit: 0
Protection level: 7/2
This machine data specifies the output for the "axis safely referenced" signal.
Signal
= 0
Axis is not safely referenced (i.e. the safe limit position monitoring is inactive!)
= 1
Axis is safely referenced
If MD bit 31 is set, then the signal is processed inverted.
Refer to MD 36980: $MA_SAFE_SVSS_DISABLE_OUTPUT
Max. input limit: –
Unit: –
Max. input limit:
Unit:
x
Max. input limit: –
Unit: –
© Siemens AG 2008 All Rights Reserved