Siemens SINUMERIK 840D sl Function Manual page 325

Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

05.08
p9532[0...15]
SI motion SLS (SG) override factor (Control Unit)
Sets the override factor for the limit value for SG2 and SG4 of the function
"safely reduced speed" (SG).
[0] = SLS (SG) override factor 0
[1] = SLS (SG) override factor 1
[2] = SLS (SG) override factor 2
[3] = SLS (SG) override factor 3
[4] = SLS (SG) override factor 4
[5] = SLS (SG) override factor 5
[6] = SLS (SG) override factor 6
[7] = SLS (SG) override factor 7
[8] = SLS (SG) override factor 8
[9] = SLS (SG) override factor 9
[10] = SLS (SG) override factor 10
[11] = SLS (SG) override factor 11
[12] = SLS (SG) override factor 12
[13] = SLS (SG) override factor 13
[14] = SLS (SG) override factor 14
[15] = SLS (SG) override factor 15
Unit:
Default value:
%
100
The actual override factor for SG2 and SG4 is selected using safety–related inputs
(SGE).
p9534[0...1]
SI motion SLP (SE) upper limit values (Control Unit)
Sets the upper limit values for the "safely limited position" function (SLP).
Index:
[0] = limit value SLP1 (SE1)
[1] = limit value SLP2 (SE2)
Unit:
Default value:
mm, degrees
100 000
The following applies when setting the SE limit values: p9534 > p9535. If this con-
dition is not fulfilled, the limit values are internally exchanged and fault F01684 ("SI
Motion: Safe software limit switch values interchanged") is output.
See also: p9501, p9535, p9562 and C01715 "SI motion: Safe limit position ex-
ceeded".
© Siemens AG 2008 All Rights Reserved
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) – 05.2008 Edition
Minimum value:
Maximum value:
0
100
Minimum value:
Maximum value:
–2 147 000
2 147 000
Data Description
8.2 Parameters for SINAMICS S120
Checksum:
Yes
Data type:
Floating point
Checksum:
Yes
Data type:
REAL32
Protection level:
4
Effective:
POWER ON
Protection level:
4
Effective:
POWER ON
8-325

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics s120

Table of Contents