Siemens SINUMERIK 840D sl Function Manual page 444

Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Diagnostics
10.1 Troubleshooting procedure
Value range of the transfer parameter
000
Parameterizing error detected when booting (different state active)
Crosswise data comparison error, SPL protective mechanism: MD 11500 –
DB18.DBX36.0
Crosswise data comparison error, stop response for SPL error: MD 10097 –
DB18.DBX36.1
001...064
Error in system variables $A_INSE(P)[01...64] (Alarm 27090/Alarm 27254)
The index value then results from a channel error signaled from the PROFIsafe
module
(Alarm 27254), that is assigned the appropriate $A_INSE(P) variable (e.g. discrep-
ancy error)
065...128
Error in the system variables $A_OUTSE(P)[01...64] (Alarm 27090/Alarm 27254).
This means, Alarm 27090 signals an internal logic error ($A_OUTSE(P) variables
differ) and Alarm 27254 signals a channel error signaled from the PROFIsafe mod-
ule that is assigned to the appropriate $A_OUTSE(P) variable (e.g. short–circuit
fault).
129...192
Error in system variables $A_INSI(P)[01...64] (only alarm 27090)
193...256
Error in system variables $A_OUTSI(P)[01...64] (only alarm 27090)
257...320
Error in system variables $A_MARKERSI(P)[01...64] (only alarm 27090)
Definition of the extended text
The file, in which the extended texts are defined, is also declared in the configura-
tion file for the alarm server (file MBDDE.INI) in the section [IndexTextFiles].
File excerpt: mbdde.ini
[IndexTextfiles]
ALSI=f:\dh\mb.dir\alsi_
We recommend that this file for the extended text is located in the HMI user directory.
Every parameter can be assigned a dedicated text in this file, whereby the text
entry is located in front of the associated parameter value (refer to the following file
excerpt).
File excerpt: alsi_gr.com
000000 0 0
000001 0 0
..
10-444
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) – 05.2008 Edition
; Example : Standard entry
"Parameterizing error MD11500/DB18.DBX36.0 or
MD10097/DB18.DBX36.1"
"User text $A_INSE(P)[01]"
© Siemens AG 2008 All Rights Reserved
05.08

Advertisement