Linear Encoder Setup (Referential Time: 5 Min.) - Roland VersaCAMM VP-540 Service Notes

Hide thumbs Also See for VersaCAMM VP-540:
Table of Contents

Advertisement

4-6 LINEAR ENCODER SETUP (Referential Time : 5min.)
This is for checking the reading of the linear encoder and for calibrating its expansion/contraction caused by
the operation environment. This operation is required when Limit Sensor, Encoder Scale or Encoder Module
is replaced or the position is adjusted.
Turn on the Sub Power SW while pressing [
1
[
] keys to enter the Service Mode.
Lower the Pinch Rollers.
2
Make sure to unload the media when it is set
on the machine.
Also, the Media Clamps must be removed.
Select [PRINT MENU]> [LINEAR ENCODER], and press
3
[ENTER] key.
], [