3-7 PUMP REPLACEMENT

Turn off the sub power, and then turn off the main power.
1
Remove the I/S Cover.
2
Unlock the Head Carriage and move it leftward by hand.
3
Remove the Pump Cover and Panel Cover.
4
When removing the Panel
Cover, remove the sensor
on the back side of the
Panel Cover and flexible
cable on the Panel Board.
SENSOR
FLEXIBLE CABLE
< Back Side >
MAIN POWER SW
< Rear View >
PUMP COVER
3-33
SCREW
I/S COVER
HOOK
HEAD CARRIAGE
PANEL COVER