4.9, Flowchart A3, describes tuning for PM motors in Open Loop Vector Control. PM motors can be used for energy
savings in reduced or variable torque applications.
From
Flowchart
A
Motorcode is known ?
For parameter E5-01
NO
(for Yaskawa PM Motors)
YES
Enter "FFFF" to parameter
E5-01
Set the motor code to
Enter the motor data into
parameter E5-01
parameters E5-02 to E5-24
Return to
Flowchart
A
Figure 4.9 Operation with Permanent Magnet Motors