Subchart A-3: Operation With Permanent Magnet Motors - YASKAWA AC Drive-A1000 Technical Manual

High performance vector control drive
Table of Contents

Advertisement

u

Subchart A-3: Operation with Permanent Magnet Motors

Note: PM motor control modes are not available on 600 V class drives, CIMR-Ao5oooooooo.
Flowchart A3 in
Figure 4.11
can be used for more energy-efficient operation in reduced or variable torque applications.
Note: 1. Although the drive sets parameters for the PG encoder during Auto-Tuning, sometimes the direction of the motor and direction of the PG
get reversed. Use parameter F1-05 to switch the direction of the PG so that it matches the motor direction.
2. Realign the Z Pulse if the PG encoder is replaced. Set T2-01 to 3 to recalibrate the drive for the new encoder.
<1> Enter the motor code to E5-01 when using a Yaskawa PM motor (SMRA Series, SSR1 Series, and SST4 Series). If using a
motor from another manufacturer, enter FFFF.
<2> Make sure the motor and load can run freely (i.e., if a brake is mounted, make sure it is released).
<3> ASR Gain Tuning automatically performs Inertia Tuning and sets parameters related to Feed Forward and the KEB Ride-Thru
function.
YASKAWA ELECTRIC SIEP C710616 31B YASKAWA AC Drive – A1000 Technical Manual
describes the setup procedure for running a PM motor in Open Loop Vector Control. PM motors
From
Flowchart
A
Motor test report/ data
sheet available?
NO
<1>
Perform PM Stationary
Auto-Tuning (T2-01 = 1)
Run the motor without load; check the rotation direction and
operation.Verify external signal commands to the drive work as desired.
Connect the load to the motor.
Is there a PG
NO
encoder on the
motor?
YES
Should the drive set ASR gain
automatically?
NO
Does the application require
any of the following drive functions?
Feed Forward
KEB 2
NO
Run the machine and check for desired
operation.
Return to
Flowchart
A
Figure 4.11 Operation with Permanent Magnet Motors
YES
Input the motor data.
<1>
(T2-01 = 0)
YES
Is the motor cable longer
than 50 meters?
NO
YES
YES
Perform PM Inertia Tuning
Perform ASR gain tuning.
(T2-01 = 8)
<2>
(T2-01 = 9).
4.4 Start-Up Flowcharts
Perform PM Stationary
Auto-Tuning for Stator
Resistance (T2-01 = 2)
<3>
4
95