D.2 European Standards
Three-Phase 200 V / 400 V Class
A – Ground the cable shield
B – Enclosure panel
C – Metal plate
D – Grounding surface (remove any
E – Drive
470
L2
L3
L3 L2 L1
J
paint or sealant)
Figure D.5 EMC Filter and Drive Installation for CE Compliance
(Three-Phase 200 V / 400 V Class)
L1
PE
PE
D
E
R/L1 S/L2 T/L3
R/L1 S/L2 T/L3
U/T1 V/T2 W/T3
U/T1 V/T2 W/T3
I
H
G
F – Motor cable (braided shield cable,
max. 20 m)
G – Motor
H – Cable clamp
I – Wiring distance as short as
possible
J – EMC noise filter
YASKAWA ELECTRIC SIEP C710606 18F YASKAWA AC Drive – V1000 Technical Manual
B
C
E
D
F
A

Hide quick links: