YASKAWA CIMR-VU BA0001 Technical Manual page 158

Ac drive-v1000 200 v class, three-phase input: 0.1 to 18.5 kw; 200 v class, single-phase input: 0.1 to 3.7 kw; 400 v class, three-phase input: 0.2 to 18.5 kw
Table of Contents

Advertisement

5.3 C: Tuning
n
Rated Current Depending on Carrier Frequency
The tables below show the drive output current depending on the carrier frequency settings. The 2 kHz value is equal to the
Normal Duty rated current, the 8/10 kHz value is equal to the Heavy Duty rated current. The carrier frequency determines the
output current linearly. Use the data below to calculate output current values for carrier frequencies not listed in the tables.
Note:
In Heavy Duty mode the maximum rated output current is equal to the 8/10 kHz value, even if the carrier frequency is reduced.
Table 5.12 200 V Class Drives with 10 kHz Heavy Duty Default Carrier Frequency
Model
BA0001
2A0001
BA0002
2A0002
BA0003
2A0004
BA0006
2A0006
Table 5.13 200 V Class Drives with 8 kHz Heavy Duty Default Carrier Frequency
Model
BA0010
2A0010
BA0012
2A0012
BA0018
2A0020
2A0030
2A0040
2A0056
2A0069
Table 5.14 400 V Class Drives with 8 kHz Heavy Duty Default Carrier Frequency
Model
4A0001
4A0002
4A0004
4A0005
4A0007
4A0009
4A0011
4A0018
4A0023
4A0031
4A0038
158
2 kHz
1.2
1.9
3.5
6.0
2 kHz
9.6
12.0
17.5
19.6
30.0
40.0
56.0
69.0
2 kHz
1.2
2.1
4.1
5.4
6.9
8.8
11.1
17.5
23.0
31.0
38.0
YASKAWA ELECTRIC SIEP C710606 18F YASKAWA AC Drive – V1000 Technical Manual
Rated Current (A)
10 kHz
0.8
1.6
3.0
5.0
Rated Current (A)
8 kHz
8.0
11.0
17.5
17.5
25.0
33.0
47.0
60.0
Rated Current (A)
8 kHz
1.2
1.8
3.4
4.8
5.5
7.2
9.2
14.8
18.0
24.0
31.0
15 kHz
0.6
1.3
2.4
4.0
15 kHz
6.4
8.8
14.0
14.0
20.0
26.4
37.6
48.0
15 kHz
0.7
1.1
2.0
2.9
3.3
4.3
5.5
8.9
10.8
14.4
18.6

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents