YASKAWA CIMR-VU BA0001 Technical Manual page 360

Ac drive-v1000 200 v class, three-phase input: 0.1 to 18.5 kw; 200 v class, single-phase input: 0.1 to 3.7 kw; 400 v class, three-phase input: 0.2 to 18.5 kw
Table of Contents

Advertisement

B.2 Parameter Table
No.
Name
b5-19
PID Setpoint Value
b5-20
PID Setpoint Scaling
b5-34
PID Output Lower Limit
<6>
b5-35
PID Input Limit
<6>
PID Feedback High Detection
b5-36
Level
PID Feedback High Level
b5-37
Detection Time
b5-38
PID Setpoint / User Display
b5-39
PID Setpoint Display Digits
b5-40
Frequency Reference
<8>
Monitor Content during PID
b5-47
Reverse Operation Selection
<5>
2 by PID Output
b6-01
Dwell Reference at Start
b6-02
Dwell Time at Start
b6-03
Dwell Frequency at Stop
b6-04
Dwell Time at Stop
Energy Saving Control
b8-01
Selection
b8-02
Energy Saving Gain
<6>
b8-03
Energy Saving Control Filter
<6>
Time Constant
Energy Saving Coefficient
b8-04
Value
360
Description
Sets the PID target value when b5-18 = 1.
Sets the units for setting/display b5-19, and for parameter
monitors U5-01 (PID Feedback) and U5-04 (PID Setpoint).
0: 0.01Hz units
1: 0.01% units (100% = max output frequency)
2: r/min (number of motor poles must be set up)
3: User-set (set to b5-38 and b5-39)
Sets the minimum output possible from the PID controller.
Limits the PID control input (deviation signal). Acts as a
bipolar limit.
Sets the PID feedback high detection level.
Sets the PID feedback high level detection delay time.
Sets the display value of U5-01 and U5-04 when the maximum
frequency is output. Changeable only if b5-20 = 3.
0 to 60000: User-Set Display if b5-20 = 3
Sets the number of digits of U5-01 and U5-04. Changeable
only if b5-20 = 3.
0: No decimal places
1: One decimal places
2: Two decimal places
3: Three decimal places
0: Display the frequency reference (U1-01) after PID
compensation has been added.
1: Display the frequency reference (U1-01) before PID
compensation has been added.
Reverses operation selection when b5-01 = 3 or 4
0: Zero limit when PID output is a negative value
1: Reverse operation when PID output is a negative value (Zero
limit if the reverse operation is prohibited by b1-04)
b6: Dwell Function
Use b6 parameters to configure dwell function operation.
The Dwell function is used to temporarily hold the frequency
when driving a motor with a heavy load.
Parameters b6-01 and b6-02 set the frequency to hold and the
time to maintain that frequency at start.
Parameters b6-03 and b6-04 set the frequency to hold and the
time to maintain that frequency at stop.
Run command
Output
Frequency
b8: Energy Saving
Use b8 parameters to configure the energy saving/conservation drive function.
Selects the Energy Savings function.
0: Disabled
1: Enabled
Sets energy savings control gain when in Open Loop Vector
Control.
Sets energy saving control filter time constant when in Open
Loop Vector Control.
Sets the Energy Saving coefficient and is used to fine
adjustments in V/f Control.
OFF
ON
b6-01
b6-03
Time
b6-04
b6-02
YASKAWA ELECTRIC SIEP C710606 18F YASKAWA AC Drive – V1000 Technical Manual
Control
Mode
Range
Def.
O
V/
P
L
f
M
V
0.00 to
0.00
A A A
100.00
%
0 to 3
1
A A A
-100.0 to
0.00
A A A
+100.0
%
0.0 to
1000.
A A A
1000.0
0%
0 to 100 100% A A A
0.0 to 25.5 1.0 s A A A
<7>
1 to 60000
A A A
<7>
0 to 3
A A A
0, 1
0
A A A
0, 1
1
A A A
0.0 to
0.0
A A A
400.0
Hz
0.0 to 10.0 0.0 s A A A
0.0 to
0.0
A A A
400.0
Hz
0.0 to 10.0 0.0 s A A A
0, 1
0
A A −
0.0 to 10.0
0.7
− A −
0.00 to
0.50
− A −
10.00
<4>
<9>
0.0 to
A −
655.00
<10>
Addr.
Pg.
Hex
1DD
143
1E2
143
19F
144
1A0
144
1A1
142
1A2
142
1FE
144
1FF
144
17F
144
17D
144
1B6
145
1B7
145
1B8
145
1B9
145
1CC
145
1CD
145
1CE
145
1CF
146

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents