B.2 Parameter Table
H1-oo
Function
Setting
44
Offset Frequency 1 Addition
45
Offset Frequency 2 Addition
46
Offset Frequency 3 Addition
47
Node Setup
<1>
60
DC Injection Braking Command
61
External Search Command 1
62
External Search Command 2
65
KEB Ride-Thru 1 (N.C.)
66
KEB Ride-Thru 1 (N.O.)
67
Communications Test Mode
68
High-Slip Braking
6A
Drive Enable
75
Up 2 Command
76
Down 2 Command
7A
KEB Ride-Thru 2 (N.C.)
7B
KEB Ride-Thru 2 (N.O.)
7C
Short-Circuit Braking (N.O.)
7D
Short-Circuit Braking (N.C.)
7E
Forward/Reverse Detection
90 to 96
DWEZ Digital Inputs 1 to 7
9F
DriveWorksEZ enable
<1> Available in drive software versions PRG: 1016 and later.
No.
Name
Terminal MA, MB and MC Function
H2-01
Selection (relay)
Terminal P1 Function Selection (open-
H2-02
collector)
Terminal P2 Function Selection (open-
H2-03
collector)
378
H1 Multi-Function Digital Input Selections
Closed: Adds d7-01 to the frequency reference.
Closed: Adds d7-02 to the frequency reference.
Closed: Adds d7-03 to the frequency reference.
Closed: Node setup for SI-S3/V enabled.
Closed: Triggers DC Injection Braking (b2-02)
Closed: Activates Current Detection Speed Search from the max. output
frequency (E1-04) if b3-01 = 0. Activates Speed Estimation Type Speed
search if b3-01 = 0.
Closed: Activates Current Detection Speed Search from the frequency
reference b3-01 = 0. Activates Speed Estimation Type Speed search if b3-01
= 0.
Open: KEB Ride-Thru 1 enabled
Closed: Normal operation
Open: Normal operation
Closed: KEB Ride-Thru 1 enabled
Tests the MEMOBUS/Modbus RS-485/422 interface.
Closed: High-Slip braking is executed. Drive stops.
Open: Drive disabled.
If this input is opened during run, then the drive will stop as specified by
parameter b1-03.
Closed: Ready for operation.
Open: Maintains the current frequency reference.
Closed: Increases or decreases the frequency reference.
UP 2 and Down 2 commands must be set in combination with each other.
The frequency reference source must be assigned to the operator (b1-01 =
"0").
Open: KEB Ride-Thru 2 enabled
Closed: Normal operation
Open: Normal operation
Closed: KEB Ride-Thru 2 enabled
Open: Normal operation
Closed: Short-Circuit Braking
Open: Short-Circuit Braking
Closed: Normal operation
Direction of rotation detection (for V/f with Simple PG Feedback)
Reserved for DWEZ input functions
Open: DWEZ enabled
Closed: DWEZ disabled
H2: Multi-Function Digital Outputs
Use H2 parameters to assign functions to the multi-function digital outputs.
Refer to H2 Multi-Function Digital Output
Settings on page
values.
YASKAWA ELECTRIC SIEP C710606 18F YASKAWA AC Drive – V1000 Technical Manual
Description
Description
379
for a description of setting
Control
Mode
V/
f
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
-
-
O
O
O
Control
Mode
Range
Def.
O
V/
P
L
f
M
V
E
A A A
0 to 192
0
A A A
<1>
2
A A A
Pg.
O
P
L
M
V
O
O
192
O
O
192
O
O
192
O
O
192
O
-
192
O
O
192
O
O
192
O
O
192
O
O
192
O
O
192
-
-
192
O
O
192
O
O
193
O
O
193
O
O
194
O
O
194
-
O
194
-
O
194
-
-
194
O
O
194
O
O
194
Addr.
Pg.
Hex
40B
195
40C
195
40D
195