YASKAWA CIMR-VU BA0001 Technical Manual page 357

Ac drive-v1000 200 v class, three-phase input: 0.1 to 18.5 kw; 200 v class, single-phase input: 0.1 to 3.7 kw; 400 v class, three-phase input: 0.2 to 18.5 kw
Table of Contents

Advertisement

No.
Name
b1-03
Stopping Method Selection
b1-04
Reverse Operation Selection
LOCAL/REMOTE Run
b1-07
Selection
Run Command Selection
b1-08
while in Programming Mode
b1-14
Phase Order Selection
Frequency Reference
b1-15
Selection 2
b1-16
Run Command Selection 2
b1-17
Run Command at Power Up
DC Injection Braking Start
b2-01
Frequency
DC Injection Braking Current Sets the DC Injection Braking current as a percentage of the
b2-02
DC Injection Braking Time/
b2-03
DC Excitation Time at Start
DC Injection Braking Time at
b2-04
Stop
Magnetic Flux Compensation
b2-08
Value
Short Circuit Brake Time at
b2-12
Start
YASKAWA ELECTRIC SIEP C710606 18F YASKAWA AC Drive – V1000 Technical Manual
Description
Selects the stopping method when the run command is
removed.
0: Ramp to Stop
1: Coast to Stop
2: DC Injection Braking to Stop
3: Coast with Timer
(A new run command is ignored if received before the timer
expires)
Permits or prohibits reverse operation.
0: Reverse enabled.
1: Reverse disabled.
Determines the operation when the Run command source is
switched from LOCAL to REMOTE or between Run source 1
and 2 while an external Run command is active at the new
source.
0: External Run command has to be cycled at the new source
to be activated.
1: External Run command at new source is accepted
immediately.
0: Run command accepted only in the operation menu.
1: Run command accepted in all menus.
2: Prohibit entering Programming Mode during Run
Sets the phase order for drive output terminals U/T1, V/T2 and
W/T3.
0 : Standard
1 : Switch phase order
Selects the frequency reference input source 2.
0: Operator - Digital preset speed d1-01 to d1-17.
1: Terminals - Analog input terminal A1 or A2
2: MEMOBUS communications
3: Option PCB
4: Pulse Input (Terminal RP)
Selects the run command input source 2.
0: Operator - RUN and STOP keys on the digital operator.
1: Digital input terminals
2: MEMOBUS communications
3: Option PCB
Determines the operation when a Run command is active at
power up of the drive.
0: Run command not issued, needs to be cycled
1: Run command issued, motor operation start
b2: DC Injection Braking
Use b2 parameters to configure DC Injection Braking operation
Sets the frequency at which DC Injection Braking starts when
Ramp to Stop (b1-03 = 0) is selected. If b2-01< E1-09, DC
Injection Braking starts at E1-09.
drive rated current.
Sets DC Injection Braking time at start. Disabled when set to
0.00 seconds.
Sets DC Injection Braking time at stop.
When b1-03 = 2, actual DC Injection time is calculated as
follows:
(b2-04) x 10 x (Output Freq)/(E1-04). When b1-03 = 0, this
parameter sets the amount of DC Injection time applied to the
motor at the end of the decel ramp or High Slip Braking.
Disabled when set to 0.00.
Sets the magnetic flux compensation as a percentage of the no-
load current value (E2-03).
Sets the time for Short-Circuit brake operation at start.
Disabled when set to 0.00.
<2>
B.2 Parameter Table
Control
Mode
Range
Def.
O
V/
P
L
f
M
V
0 to 3
0
S
S
S
DC Injection Braking at Stop cannot be
selected when using Open Loop Vector for PM
motors.
0, 1
0
A A A
0, 1
0
A A A
0 to 2
0
A A A
0, 1
0
A A A
0 to 4
0
A A A
0 to 3
0
A A A
0, 1
0
A A A
0.5
0.0 to 10.0
A A A
Hz
0 to 75
50% A A A
0.00 s
0.00 to
A A A
<1>
10.00
0.00 to
0.50 s A A −
10.00
0 to 1000
0%
− A −
0.00 to
0.00 s −
− A
25.50
Addr.
Pg.
Hex
182
124
183
126
186
127
187
127
1C3
127
1C4
128
1C5
128
1C6
128
189
128
18A
129
18B
129
18C
129
B
190
129
1BA
129
357