No.
Name
U2-02
Previous Fault
Frequency Reference at
U2-03
Previous Fault
Output Frequency at Previous
U2-04
Fault
Output Current at Previous
U2-05
Fault
Motor Speed at Previous Fault
U2-06
Output Voltage at Previous
U2-07
Fault
DC Bus Voltage at Previous
U2-08
Fault
Output Power at Previous
U2-09
Fault
Torque Reference at Previous
U2-10
Fault
Input Terminal Status at
U2-11
Previous Fault
Output Terminal Status at
U2-12
Previous Fault
Drive Operation Status at
U2-13
Previous Fault
Cumulative Operation Time
U2-14
at Previous Fault
Soft Starter Speed Reference
U2-15
at Previous Fault
Motor q-Axis Current at
U2-16
Previous Fault
Motor d-Axis Current at
U2-17
Previous Fault
U3-01
Most Recent Fault
U3-02
2nd Most Recent Fault
U3-03
3rd Most Recent Fault
U3-04
4th Most Recent Fault
U3-05
5th Most Recent Fault
U3-06
6th Most Recent Fault
U3-07
7th Most Recent Fault
U3-08
8th Most Recent Fault
U3-09
9th Most Recent Fault
U3-10
10th Most Recent Fault
Cumulative Operation Time
U3-11
at Most Recent Fault
YASKAWA ELECTRIC SIEP C710606 18F YASKAWA AC Drive – V1000 Technical Manual
Description
Displays the previous fault.
Displays the frequency reference at the previous fault.
Displays the output frequency at the previous fault.
Displays the output current at the previous fault.
Displays the motor speed at the previous fault.
Displays the output voltage at the previous fault.
Displays the DC bus voltage at the previous fault.
Displays the output power at the previous fault.
Displays the torque reference at the previous fault.
Displays the input terminal status at the previous fault.
Displayed as in U1-10.
Displays the output status at the previous fault. Displays the
same status displayed in U1-11.
Displays the operation status of the drive at the previous
fault. Displays the same status displayed in U1-12.
Displays the cumulative operation time at the previous fault.
Displays the run speed after a soft start when a previous fault
occurred. Displayed as in U1-16.
Displays the q-axis current for the motor at the previous fault.
Displays the d-axis current for the motor at the previous fault. No signal output
U3: Fault History
Use U3 monitors to display fault data.
Displays the most recent fault.
Displays the second most recent fault.
Displays the third most recent fault.
Displays the fourth most recent fault.
Displays the fifth most recent fault.
Displays the sixth most recent fault.
Displays the seventh most recent fault.
Displays the eighth most recent fault.
Displays the ninth most recent fault.
Displays the tenth most recent fault.
Displays the cumulative operation time at the most recent
fault.
B.2 Parameter Table
Analog Output
Unit
Level
No signal output
avail.
No signal output
0.01
avail.
Hz
No signal output
0.01
avail.
Hz
<1>
No signal output
avail.
<2>
No signal output
0.01
avail.
Hz
No signal output
0.1 V A A A
avail.
No signal output
1 V
avail.
No signal output
0.1
avail.
kW
No signal output
0.1% − Α −
avail.
No signal output
avail.
No signal output
avail.
No signal output
avail.
No signal output
1 H
avail.
No signal output
0.01
avail.
%
No signal output
0.10
avail.
%
0.10
avail.
%
<3>
No signal output
avail.
No signal output
avail.
No signal output
avail.
No signal output
avail.
No signal output
avail.
No signal output
avail.
No signal output
avail.
No signal output
avail.
No signal output
avail.
No signal output
avail.
No signal output
1 h
avail.
Control
Mode
Addr.
O
Hex
V/
P
L
f
M
V
A A A
81
A A A
82
A A A
83
A A A
84
− A −
85
86
A A A
87
A A A
88
89
A A A
8A
A A A
8B
A A A
8C
A A A
8D
A A A
7E0
A A A
7E1
− A A
7E2
90
A A A
(800)
91
A A A
(801)
92
A A A
(802)
93
A A A
(803)
A A A
804
A A A
805
A A A
806
A A A
807
B
A A A
808
A A A
809
94
A A A
(80A)