4.3 The Drive and Programming Modes
Programming
Mode
Drive Mode
n
Drive Mode Details
The following actions are possible in the Drive Mode:
• Run and stop the drive.
• Monitor the operation status of the drive (frequency reference, output frequency, output current, output voltage, etc.).
• View information on an alarm.
• View a history of alarms that have occurred.
Note:
Select "Drive Mode" when running. The mode can be switched to any mode (program mode, etc.) other than drive mode while the drive is
stopped. However, the drive cannot be operated in other modes. Return the mode to "Drive Mode" after completing periodic inspection.
Figure 4.4
illustrates changing the default frequency reference of F 0.00 (0 Hz) to F 6.00 (6 Hz) while in Drive Mode. This
example assumes the drive is set to LOCAL.
Frequency reference
display at power up
STOP
Press until the frequency
reference becomes 6 Hz
Note:
The drive will not accept a frequency reference set value unless the ENTER key is pressed after the frequency reference is entered. This
feature prevents accidental setting of the frequency reference. By setting o2-05 (Frequency Reference Setting Method Selection) to 1
(Enabled), the drive will accept the frequency reference while it is being adjusted on the digital operator.
86
Verify Function
STOP
Setup
STOP
Parameter Setting
STOP
Auto-Tuning
STOP
Frequency Reference
STOP
Press to select LOCAL
Figure 4.4 Setting the Frequency Reference while in Drive Mode
Lists all parameters that have been edited or changed from default settings.
Verifying Parameter Changes: Verify Menu on page
A select list of parameters necessary to get the drive operational quickly.
Setup Group within the Programming Mode on page
Note: Parameters to be displayed differ depending on the setting of A1-06 (Application
Preset).
Refer to Application Selection on page
Allows the user to access and edit all parameter settings.
page
353.
Motor parameters are calculated and set automatically.
102.
Returns to the frequency reference display screen.
YASKAWA ELECTRIC SIEP C710606 18F YASKAWA AC Drive – V1000 Technical Manual
88.
87.
96.
Refer to Parameter List on
Refer to Auto-Tuning on page
Press to select the
digit to the right
Refer to
Refer to The