ST-12
-
STARTER
STARTING
Tighten terminal nut.
(g)
Put a wooden block on the contact plate and press
( 1 )
it down with a hand press.
Dimensions of wooden block:
20
37
X
X
Press force:
981 N (100 kgf, 221 lbf)
NOTICE:
Check the diameter of the hand press ram. Then calculate
the gauge pressure of the press when 981 N (100 kgf, 221
lbf) of force is applied.
Gauge pressure:
=
(kgflcm 2 )
=
(psi)
.::: (kgflcm2)
(kpa)
=
( k
)
pa
(psi)
If the contact plate
sure, the contact plate may tilt due to coil deformation or the
tightening of the nut.
Using SST, tighten the nuts to the specified torque.
(2)
SST
09810-38140
Torque: 1 7 N-m (173 kgf.cm, 1 2 11-lbf)
NOTICE:
If the nut Is over tightened, it may cause cracks on the In�
SST
side of the insulator.
""" '
Clean contact surtaces of contact plate and plunger.
(h)
Clean the contact surtaces of the remaining contact plate
and plunger with a dry shop rag.
Reinstall magnetlc switch end cover.
(i)
Instal! the plunger, new gasket, end cover with tho
Torque: 2.5 N-m (26 kgf.cm, 23 in.-lbf)
40 mm (0.79
1.57 in.)
1 .46
X
X
2
100
kgf
x
Ram dia
221
ibf
2
x
3.14 (n}
x
98.1
x 6.9
i s
not pressed down with the specified pres­
3 . 14(11)
bolts.