5 - 380 WiNG 5.7.1 Access Point System Reference Guide
(downstream). Existing rate limit configurations display along with their virtual connection protocols and data traffic QoS
customizations.
36. Select
Add
to create a new rate limit configuration or
Figure 5-256 Device Overrides - Advanced Profile MINT screen - Add Rate Limits screen
37. Set the following
Level
Protocol
Link Type
Rate Limits
to complete the MINT configuration:
Select level2 to apply rate limiting for all links on level2.
Select either mlcp or link as this configuration's rate limit protocol. Mint Link Creation
Protocol (MLCP) creates a UDP/IP link from the device to a neighbor. The neighboring
device does not need to be a controller or service platform, it can be an access point
with a path to the controller or service platform. Select link to rate limit using
statically configured MiNT links.
Select either VLAN, to configure a rate limit configuration on a specific virtual LAN, or
IP to set rate limits on a static IP address/Port configuration.