FIRMWARE HISTORY
DESCRIPTION OF MODIFICATION
1. Network connection is broken.
2. Panel freezes when multiple buttons are
pressed continuously.
Other changes:
1. The following IP protocols can be
enabled/disabled: HTTP, Telnet, FTP,
SNMP, IPP, LPR, and Rawsocket.
2. SNMP Community name can be
changed.
3. SAP interval can be changed.
4. Software now supports NetWare 6.
5. SNMP security improved (CERT test
path).
Note 1: IPP printing
Only G049 and G054 support this feature. (not supported by G031/G032)
Windows 2000 or Windows 98/ME allow IPP printing. IPP client program must be installed in
Windows 98/ME before using the feature. The IPP client program, WPNPINS.exe, is on the
Microsoft Web site.
With the Add printer wizard, an IPP port can be specified as follows:
URL) http://XXX.XXX.XXX:631/Print
Note 2: Network speed
The network speed can be fixed at100Mbps or 10Mbps by built-in web browser.
Be aware that the machine will never communicate with the host if the wrong network speed
has been set by accident.
G031/G032
G919 NIB FIRMWARE MODIFICATION HISTORY
XXX is the IP address of the printer.
FIRMWARE
LEVEL
Rst576c.upd
10-18
Rev. 01/2003
SERIAL
FIRMWARE
NUMBER
VERSION
5.76c
Sept. '02