12 March 1999

6.2.5 FUSING DRAWER CONNECTOR REPLACEMENT

[C]
1. Remove the hot roller. (Refer to Hot Roller and Fusing Lamp Replacement,
section 6.2.2.)
2. Remove the two screw covers [A] (230 V machine only, 1 screw each).
3. Remove the screw [B] securing the thermistor.
4. Remove the two cable covers [C] (1 screw each).
NOTE: When re-installing the cable covers, secure the cable under the cover
correctly.
5. Remove the three screws [D] securing the cable.
6. Replace the fusing drawer connector [E] (1 screw).
SM
[E]
[D]
[C]
6-9
FUSING UNIT
[B]
[A]
[D]
G031R545.WMF