6Xxxyyyy Srcs - IBM Flex System p260 Installation And Service Manual

Hide thumbs Also See for Flex System p260:
Table of Contents

Advertisement

11008414 • 110084A0
11008414
Explanation: Invalid processor 2 VPD.
Response:
1. Search RETAIN tips and the firmware change history for the reference code to determine the recommended
actions. If a firmware update is needed, see Updating the firmware
2. Replace the system board. If there is more than one system board, use the location code in the SRC to identify
which system board to replace.
11008423
Explanation: No processor VPD was found.
Response:
1. Search RETAIN tips and the firmware change history for the reference code to determine the recommended
actions. If a firmware update is needed, see Updating the firmware
2. Replace the base system-board, as described in Replacing the system-board and chassis assembly.
11008447
Explanation: SSD interposer card pGood fault on the system board.
Response:
1. Replace the interposer card specified by the location code in the error log entry.
11008480
Explanation: Bad or missing memory controller.
Response:
1. Search RETAIN tips and the firmware change history for the reference code to determine the recommended
actions. If a firmware update is needed, see Updating the firmware
2. Replace the system board. If there is more than one system board, use the location code in the SRC to identify
which system board to replace.
110084A0
Explanation: No backplane VPD was found.
Response:
1. Check for server firmware updates.
2. Apply any available updates.
3. Search RETAIN tips and the firmware change history for the reference code to determine the recommended
actions. If a firmware update is needed, see Updating the firmware
4. Replace the base system-board, as described in Replacing the system-board and chassis assembly.

6xxxyyyy SRCs:

The 6xxxyyyy system reference codes are virtual optical reference codes.
Find the system reference code in the list below. Follow the suggested actions in the order in which they
are listed until the problem is solved. If an action solves the problem, then you can stop performing the
remaining actions. See Chapter 7, "Parts listing for IBM Flex System p260 and p460 Compute Nodes," on
page 97 to determine which components are CRUs and which components are FRUs.
128
Power Systems: IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide