IBM Flex System p260 Installation And Service Manual page 382

Hide thumbs Also See for Flex System p260:
Table of Contents

Advertisement

26D7-128 • 26D7-134
26D7-128
Explanation: The error log analysis indicates a hardware failure. Replace each part reported by the diagnostic
program one at a time. Run the diagnostic program in problem determination mode on each part reported in the
original SRN. If the problem persists, replace the next part in the list.
Response:
Failing Item:
v FFC_B88
v FFC_26D7
26D7-129
Explanation: Error log analysis indicates a SCSI bus problem. Replace each part reported by the diagnostic program
one at a time. Run the diagnostic program in problem determination mode on each part reported in the original SRN.
If the problem persists, replace the next part in the list.
Response:
Failing Item:
v FFC_B88
v FFC_26D7
26D7-130
Explanation: Error log analysis indicates a problem reported by the disk drive's self-monitoring function. Replace
the 900 GB SFF SAS Hard Disk Drive.
Response:
Failing Item:
v FFC_26D7
26D7-132
Explanation: A disk drive hardware error occurred. Replace the 900 GB SFF SAS Hard Disk Drive.
Response:
Failing Item:
v FFC_26D7
26D7-134
Explanation: The adapter failed to configure. Replace each part reported by the diagnostic program one at a time.
Retry the diagnostic test after each part is replaced. If the problem persists, replace the next part in the list.
Response:
Failing Item:
v FFC_B88
v SOFTWARE