Explanation: Failure to initialize due to a problem while reading the EEPROM on the adapter. Replace the IBM Flex
System EN4054 4-port 10Gb Ethernet Adapter.
Response:
Failing Item:
v FFC_2E37
2E3D-101
Explanation: PCI Configuration Registers Test Failure. Replace the IBM Flex System EN2024 4-port 1Gb Ethernet
Adapter If the problem persists, replace the system board.
Response:
Failing Item:
v FFC_2E3D
v FFC_221
2E3D-102
Explanation: I/O Registers Test Failure. Replace the IBM Flex System EN2024 4-port 1Gb Ethernet Adapter
Response:
Failing Item:
v FFC_2E3D
2E3D-103
Explanation: NVRAM and Checksum Verification Failure. Replace the IBM Flex System EN2024 4-port 1Gb Ethernet
Adapter
Response:
Failing Item:
v FFC_2E3D
2E3D-104
Explanation: Adapter Memory Test Failure. Replace the IBM Flex System EN2024 4-port 1Gb Ethernet Adapter
Response:
Failing Item:
v FFC_2E3D