B7006955
Explanation: Informational system log entry only.
Response: No corrective action is required.
B7006956
Explanation: An NVRAM failure was detected.
Response: Go to Isolating firmware problems.
B7006965
Explanation: Informational system log entry only.
Response: No corrective action is required.
B7006970
Explanation: PCI host bridge failure
Response:
1. Replace the system-board, as described in Replacing the system-board and chassis assembly.
2.
If the problem persists, use the PCI expansion card (PIOCARD) problem isolation procedure to determine the
failing component.
B7006971
Explanation: PCI bus failure
Response:
1. Use the PCI expansion card (PIOCARD) problem isolation procedure to determine the failing component.
2. If the problem persists, replace the system-board and chassis assembly, as described in Replacing the
system-board and chassis assembly.
B7006972
Explanation: System bus error
Response: Replace the system-board and chassis assembly, as described in Replacing the system-board and chassis
assembly.
B7006973
Explanation: System bus error
Response:
1. Use the PCI expansion card (PIOCARD) problem isolation procedure to determine the failing component.
2. If the problem persists, replace the system-board and chassis assembly, as described in Replacing the
system-board and chassis assembly.
B7006955 • B7006973