IBM Flex System p260 Installation And Service Manual page 156

Hide thumbs Also See for Flex System p260:
Table of Contents

Advertisement

B15611B1 • B1817203
B15611B1
Explanation: The service processor could not communicate with the Chassis Management Module.
Response: Go to Reseating the compute node in a chassis.
B15611B9
Explanation: The service processor could not communicate with the Chassis Management Module.
Response: Go to Reseating the compute node in a chassis.
B15611BA
Explanation: The service processor could not communicate with the Chassis Management Module.
Response: Go to Reseating the compute node in a chassis.
B1768BBF
Explanation: During the configuration of the second interface connection, the service processor detected that the
interface is not connected to an active CMM.
Response: If a service processor reset to factory default was performed or if this is a tracking event, no service
actions are required. Otherwise, use the FRU and procedure callouts detailed with the SRC to determine service
actions.
B1817200
Explanation: Invalid boot request
Response: Go to Checkout procedure.
B1817201
Explanation: Service processor failure
Response: Go to Checkout procedure.
B1817202
Explanation: The permanent and temporary firmware sides are both marked invalid
Response: Go to Checkout procedure.
B1817203
Explanation: Error setting boot parameters
Response: Go to Checkout procedure.