IBM Flex System p260 Installation And Service Manual page 187

Hide thumbs Also See for Flex System p260:
Table of Contents

Advertisement

B7004402 • B70047CB
B7004402
Explanation: A system firmware error occurred while attempting to allocate the memory necessary to create a
platform dump.
Response: Go to Isolating firmware problems.
B7004705
Explanation: System firmware failure. A problem occurred when initializing, reading, or using the system VPD. The
Capacity on Demand function is not available.
Response: Restart the system.
B7004710
Explanation: Informational system log entry only.
Response: No corrective action is required.
B7004714
Explanation: Informational system log entry only.
Response: No corrective action is required.
B7004715
Explanation: A problem occurred when initializing, reading, or using system VPD.
Response: Replace the management card, as described in Removing the management card and Installing the
management card.
B7004750
Explanation: Informational system log entry only.
Response: No corrective action is required.
B7004788
Explanation: Informational system log entry only.
Response: No corrective action is required.
B70047CB
Explanation: Informational system log entry only.
Response: No corrective action is required.
175
Chapter 8. Troubleshooting