IBM Flex System p260 Installation And Service Manual page 220

Hide thumbs Also See for Flex System p260:
Table of Contents

Advertisement

BA060201 • BA090001
BA060201
Explanation: Failed to read the VPD "boot path" field value
Response:
1. Reboot the server.
2. Search RETAIN tips and the firmware change history for the reference code to determine the recommended
actions. If a firmware update is needed, see Updating the firmware
BA060202
Explanation: Failed to update the VPD with the new "boot path" field value
Response:
1. Reboot the server.
2. Search RETAIN tips and the firmware change history for the reference code to determine the recommended
actions. If a firmware update is needed, see Updating the firmware
BA060300
Explanation: An I/O error on the adapter from which the boot was attempted prevented the operating system from
being booted.
Response:
1. Using the SMS menus, select another adapter from which to boot the operating system, and reboot the system.
2. Attempt to reboot the system.
3. Go to Boot problem resolution.
BA07XXXX
Explanation: self configuring SCSI device (SCSD) controller failure
Response:
1. Reboot the server.
2. Search RETAIN tips and the firmware change history for the reference code to determine the recommended
actions. If a firmware update is needed, see Updating the firmware
BA090001
Explanation: SCSD DASD: test unit ready failed; hardware error
Response:
1. Reboot the server.
2. Search RETAIN tips and the firmware change history for the reference code to determine the recommended
actions. If a firmware update is needed, see Updating the firmware
208
Power Systems: IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Flex system p460

Table of Contents