CA00E175 • CA00E178
CA00E175
Explanation: Bootp request
Response:
1. Verify that:
v The bootp server is correctly configured; then, retry the operation.
v The network connections are correct; then, retry the operation.
2. If the problem persists:
a. Go to Checkout procedure.
b. Replace the system-board, as described in Replacing the system-board and chassis assembly.
CA00E176
Explanation: TFTP file transfer
Response:
1. Verify that:
v The bootp server is correctly configured; then, retry the operation.
v The network connections are correct; then, retry the operation.
2. If the problem persists:
a. Go to Checkout procedure.
b. Replace the system-board, as described in Replacing the system-board and chassis assembly.
CA00E177
Explanation: Transfer failure due to TFTP error condition
Response:
1. Verify that:
v The bootp server is correctly configured; then, retry the operation.
v The network connections are correct; then, retry the operation.
2. If the problem persists:
a. Go to Checkout procedure.
b. Replace the system-board, as described in Replacing the system-board and chassis assembly.
CA00E178
Explanation: Initiating TFTP file transfer
Response:
1. Verify that:
v The bootp server is correctly configured; then, retry the operation.
v The network connections are correct; then, retry the operation.
2. If the problem persists:
a. Go to Checkout procedure.
b. Replace the system-board, as described in Replacing the system-board and chassis assembly.