IBM Flex System p260 Installation And Service Manual page 422

Hide thumbs Also See for Flex System p260:
Table of Contents

Advertisement

950-2D14 • 2506-3010
950-2D14
Explanation: A resource was not detected that was previously installed. Check the Management Module event log
for an system event. If there is not a system error, replace the system board (SAS controller).
Response:
Failing Item:
v FFC_2D14
950-2D29
Explanation: A resource was not detected that was previously installed. Check the Management Module event log
for an system event. If there is not a system error, replace the PCIe x8 Internal 3Gb SAS Adapter.
Response:
Failing Item:
v FFC_2D29
2506-102E
Explanation: Reallocation failed due to disk out of alternate sectors. Go to Performing the checkout procedure.
Response:
Failing Item:
v FFC_722
2506-3002
Explanation: Addressed device failed to respond to selection. Go to Performing the checkout procedure.
Response:
Failing Item:
v FFC_722
2506-3010
Explanation: Disk returned wrong response to adapter. Go to Performing the checkout procedure.
Response:
Failing Item:
v FFC_722
410
Power Systems: IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide