26B4-132 • 26B4-136
26B4-132
Explanation: A disk drive hardware error occurred. Replace each part reported by the diagnostic program one at a
time. Retry the diagnostic test after each part is replaced. If the problem persists, replace the next part in the list.
Response:
Failing Item:
v FFC_26B4
v FFC_26BD
26B4-134
Explanation: The adapter failed to configure. Replace each part reported by the diagnostic program one at a time.
Retry the diagnostic test after each part is replaced. If the problem persists, replace the next part in the list.
Response:
Failing Item:
v FFC_B88
v SOFTWARE
26B4-135
Explanation: The device failed to configure. Replace each part reported by the diagnostic program one at a time.
Retry the diagnostic test after each part is replaced. If the problem persists, replace the next part in the list.
Response:
Failing Item:
v SOFTWARE
v FFC_26B4
v FFC_26BD
v FFC_B88
26B4-136
Explanation: The certify operation failed. Replace the 200 GB SATA Solid State Drive.
Response:
Failing Item:
v FFC_26B4