IBM Flex System p260 Installation And Service Manual page 184

Hide thumbs Also See for Flex System p260:
Table of Contents

Advertisement

B7000650 • B7000A10
B7000650
Explanation: System firmware detected an error. Resource management was unable to allocate main storage. A
platform dump was initiated.
Response:
1. Collect the event log.
2. Collect the platform dump data.
3. Collect the partition configuration information.
4. Go to Isolating firmware problems.
B7000651
Explanation: The system detected an error in the system clock hardware
Response: Replace the system-board and chassis assembly, as described in Replacing the system-board and chassis
assembly.
B7000803
Explanation: Informational system log entry only.
Response: No corrective action is required.
B7000804
Explanation: Informational system log entry only.
Response: No corrective action is required.
B7000A00
Explanation: Informational system log entry only.
Response: No corrective action is required.
B7000A01
Explanation: Informational system log entry only.
Response: No corrective action is required.
B7000A10
Explanation: Informational system log entry only.
Response: No corrective action is required.
172
Power Systems: IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide