2506-9021 • 2506-9027
2506-9021
Explanation: Two or more disks are missing from a RAID-5 or RAID 6 Disk Array. Go to Performing the checkout
procedure.
Response:
2506-9022
Explanation: Two or more disks are missing from a RAID-5 or RAID 6 Disk Array. Go to Performing the checkout
procedure.
Response:
2506-9023
Explanation: One or more Disk Array members are not at required physical locations. Go to Performing the
checkout procedure.
Response:
2506-9024
Explanation: Physical location of Disk Array members conflict with another Disk Array. Go to Performing the
checkout procedure.
Response:
2506-9025
Explanation: Incompatible disk installed at degraded disk location in Disk Array. Go to Performing the checkout
procedure.
Response:
2506-9026
Explanation: Previously degraded disk in Disk Array not found at required physical location. Go to Performing the
checkout procedure.
Response:
2506-9027
Explanation: Disk Array is or would become degraded and parity data is out of synchronization. Go to Performing
the checkout procedure.
Response: