IBM Flex System p260 Installation And Service Manual page 165

Hide thumbs Also See for Flex System p260:
Table of Contents

Advertisement

B2003114 • B2003140
B2003114
Explanation: A problem occurred during the startup of a partition.
Response: Look for other errors and resolve them.
B2003120
Explanation: Informational system log entry only.
Response: No corrective action is required.
B2003123
Explanation: Informational system log entry only.
Response: No corrective action is required.
B2003125
Explanation: During the startup of a partition, the server firmware could not obtain a segment of main storage
within the server to use for managing the creation of a partition.
Response: Check for server firmware updates; then, install the updates if available.
B2003128
Explanation: A problem occurred during the startup of a partition. A return code for an unexpected failure was
returned when attempting to query the load source path.
Response: Look for and resolve B700 69xx errors.
B2003130
Explanation: A problem occurred during the startup of a partition.
Response: Check for server firmware updates; then, install the updates if available.
B2003135
Explanation: A problem occurred during the startup of a partition.
Response: Check for server firmware updates; then, install the updates if available.
B2003140
Explanation: A problem occurred during the startup of a partition. This is a configuration problem in the partition.
Response: Reconfigure the partition to include the intended load source path.
153
Chapter 8. Troubleshooting

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Flex system p460

Table of Contents