Troubleshoot system reference code (SRC) data

There can be problems with your Operations Console configuration if you receive
any of the following system reference codes (SRCs):
SRCs A6005001, A6005004, A6005007, B6005001, B6005004,
and B6005007
The following reference codes may be displayed for twinaxial consoles as well as
Operations Console (directly attached) consoles.
A6005001 and B6005001
A console resource (controller) was not found during a manual IPL.
A6005004 and B6005004
A console device was not found during a manual IPL. A twinaxial controller was
found but may not be used. This is only indicating the presence of a controller. It
is not indicating the controller may be defective.
A6005007 and B6005007
A console device was not found during a manual IPL. This reference code is also
indicating the presence of hardware that may indicate another console type other
than twinaxial or Operations Console (Direct) was found. An example would be
the old async console, no longer supported. This is not indicating a failure of that
hardware or that this is the intended console.
These reference codes, as well as the attention light, will be reset when a console is
detected and becomes active. It is possible that an IPL will be necessary to attempt
finding a console device again if one of these reference codes exists for a long
period of time, depending on many factors, including model, hardware present,
etc. You can force the server to try finding the console again by doing a function 21
from the control panel, remote control panel, or virtual control panel.

SRCs A6005001, A6005004, A6005007, B6005001, B6005004, and B6005007

Solutions for SRCs A6005001, A6005004, A6005007, B6005001, B6005004, and
B6005007.
SRCs A6005008 and B6005008
Solutions for SRCs A6005008 and B6005008.
System reference code A9002000
Solutions for system reference code A9002000.
System reference code A6005082
Solutions for system reference code A6005082.
Failure to display D1008065 and D1008066 automatically after calling the
function
Solutions for failure to post D1008065 and D1008066 automatically after
invoking the function.
IPL step C6004031 takes longer than expected
Solutions for V5R1 and later IPL step at C6004031 may take 45 minutes.