2E29-604
Explanation: Adapter down error Replace the IBM Flex System CN4058 8-port 10Gb Converged Adapter
Response:
Failing Item:
v FFC_2E29
2E33-201
Explanation: Adapter configuration error.
1. Check the BladeCenter management-module event log. If an error was recorded by the system, see POST progress
codes (checkpoints).
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board
Response:
Failing Item:
v FFC_2E33
v FFC_221
2E33-601
Explanation: Download firmware error.
1. Check the BladeCenter management-module event log. If an error was recorded by the system, see POST progress
codes (checkpoints).
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board
Response:
Failing Item:
v FFC_2E33
2E33-602
Explanation: EEPROM read error.
1. Check the BladeCenter management-module event log. If an error was recorded by the system, see POST progress
codes (checkpoints).
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board
Response:
Failing Item:
v FFC_2E33
2E29-604 • 2E33-602