IBM Flex System p260 Installation And Service Manual page 443

Hide thumbs Also See for Flex System p260:
Table of Contents

Advertisement

2D29-4101 • 2D29-8150
2D29-4101
Explanation: Temporary device bus fabric error. Use MAP3152 to determine resolution.
Response:
2D29-4110
Explanation: Unsupported enclosure function detected. Use MAP3145 to determine resolution.
Response:
2D29-4150
Explanation: PCI bus error detected by controller. Replace the PCIe x8 Internal 3Gb SAS Adapter.
Response:
Failing Item:
v FFC_2D29
2D29-4160
Explanation: PCI bus error detected by controller. Replace the PCIe x8 Internal 3Gb SAS Adapter.
Response:
Failing Item:
v FFC_2D29
2D29-7001
Explanation: Temporary disk data error. Replace the PCIe x8 Internal 3Gb SAS Adapter.
Response:
Failing Item:
v FFC_722
2D29-8150
Explanation: Controller failure. Replace the PCIe x8 Internal 3Gb SAS Adapter.
Response:
Failing Item:
v FFC_2D29
431
Chapter 8. Troubleshooting