25C4-602 • 2604-104
25C4-602
Explanation: EEPROM read error. Go to Performing the checkout procedure.
Response:
Failing Item:
v FFC_25C4
25C4-701
Explanation: Permanent adapter failure. Go to Performing the checkout procedure.
Response:
Failing Item:
v FFC_25C4
25C4-XXX
Explanation: Generic reference for Broadcom adapter. Go to Performing the checkout procedure.
Response:
Failing Item:
v FFC_25C4
2604-102
Explanation: Reset Test failure for the Fibre Channel adapter card. Replace the 4Gb Fibre Channel Adapter card.
Response:
Failing Item:
v FFC_2604
2604-103
Explanation: Register Test failure for the Fibre Channel adapter card. Replace the 4Gb Fibre Channel Adapter card.
Response:
Failing Item:
v FFC_2604
2604-104
Explanation: SRAM Test failure for the Fibre Channel adapter card. Replace the 4Gb Fibre Channel Adapter card.
Response:
Failing Item:
v FFC_2604
335
Chapter 8. Troubleshooting