IBM Flex System p260 Installation And Service Manual page 196

Hide thumbs Also See for Flex System p260:
Table of Contents

Advertisement

B70069C3 • B70069F2
B70069C3
Explanation: Informational system log entry only.
Response: No corrective action is required.
B70069D9
Explanation: Host Ethernet Adapter (HEA) failure.
Response: Replace the system-board and chassis assembly, as described in Replacing the system-board and chassis
assembly.
B70069DA
Explanation: Informational system log entry only.
Response: No corrective action is required.
B70069DB
Explanation: System firmware failure.
Response:
1. Collect the platform dump information.
2. Go to Isolating firmware problems.
B70069F1
Explanation: I/O Controller had a permanent unrecoverable failure.
Response: If there are any Operating System errors logged against I/O adapters, do not replace any I/O adapter
hardware. This I/O Controller failure is the root cause.
1. Collect error logs and informational logs.
2. Replace the system-board and chassis assembly, as described in Replacing the system-board and chassis assembly.
3. Although the partition or application may have continued to run after the I/O adapter failures, it might need to
be restarted to recover.
B70069F2
Explanation: I/O Controller had a temporary failure which has been recovered. Do not replace any FRUs.
Response: If there are any Operating System errors logged against I/O adapters, do not replace any I/O adapter
hardware. This I/O Controller failure is the root cause.
1. Collect error logs and informational logs.
2. Although the partition or application may have continued to run after the failure, it might need to be restarted to
recover.
184
Power Systems: IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide