2627-201 • 2627-702
2627-201
Explanation: Loop back test failure. Do the following steps one at a time, in order, and rerun the test after each step:
1. Reseat the cable.
2. Replace the cable.
3. Verify that the network is functional.
4. Verify that the network switch is functional.
Response:
Failing Item:
v CABLE
v NETWORK
2627-301
Explanation: Loop back test failure. Do the following steps one at a time, in order, and rerun the test after each step:
1. Reseat the cable.
2. Replace the cable.
3. Verify that the network is functional.
4. Verify that the network switch is functional.
5. Go to Performing the checkout procedure.
Response:
Failing Item:
v CABLE
v NETWORK
v FFC_2627
2627-701
Explanation: Error Log Analysis indicates that this adapter has failed due to an internal error. Replace the IBM Flex
System IB6132 QDR InfiniBand Adapter.
Response:
Failing Item:
v FFC_2627
2627-702
Explanation: Error Log Analysis indicates that this adapter has failed due to a failure with the uplink interface used
to connect this device to the host processor. Replace the IBM Flex System IB6132 QDR InfiniBand Adapter.
Response:
Failing Item:
v FFC_2627
348
Power Systems: IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide