6Xxxyyyy Srcs - IBM PS703 Service Manual

7891-73x;7891-74x
Hide thumbs Also See for PS703:
Table of Contents

Advertisement

Table 10. 1xxxyyyy SRCs (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v See Chapter 3, "Parts listing, type 7891," on page 225 to determine which components are CRUs and which
components are FRUs.
1xxxyyyy
Error
Description
Codes
8414
Invalid processor 2 VPD
8423
No processor VPD was found
8447
SSD interposer card pGood
fault
8480
Bad or missing memory
controller VID

6xxxyyyy SRCs

The 6xxxyyyy system reference codes are virtual optical reference codes.
Look for the rightmost 4 characters (yyyy in 6xxxyyyy) in the error code; this is the reference code. Find
the reference code in Table 11.
Table 11. 6xxxyyyy SRCs
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v See Chapter 3, "Parts listing, type 7891," on page 225 to determine which components are CRUs and which
components are FRUs.
6xxxyyyy
Description
Error Codes
632Byyyy codes are Network File System (NFS) virtual optical SRCs
Action
1. Go to "Checkout procedure" on page 176.
2. Perform one of the following:
a. If the location code reported with this SRC is Un-P2, replace
the expansion system-board assembly, as described in
"Removing the expansion unit for a PS704 blade server" on
page 237.
b. If the location code reported with this SRC is Un-P1, replace
the base system-board and chassis assembly, as described in
"Replacing the FRU system-board and chassis assembly" on
page 264.
1. Go to "Checkout procedure" on page 176.
2. Replace the base system-board (Un-P1) and chassis assembly, as
described in "Replacing the FRU system-board and chassis
assembly" on page 264.
Replace the interposer card on the base system planar, Un-P1-C18.
1. Go to "Checkout procedure" on page 176.
2. Perform one of the following:
a. If the location code reported with this SRC is Un-P2, replace
the expansion system-board assembly, as described in
"Removing the expansion unit for a PS704 blade server" on
page 237.
b. If the location code reported with this SRC is Un-P1, replace
the base system-board and chassis assembly, as described in
"Replacing the FRU system-board and chassis assembly" on
page 264.
Action
33
Chapter 2. Diagnostics