2D14-4010 • 2D14-4100
2D14-4010
Explanation: Configuration error, incorrect connection between cascaded enclosures. Use MAP3142 to determine
resolution.
Response:
2D14-4020
Explanation: Configuration error, connections exceed IOA design limits. Use MAP3143 to determine resolution.
Response:
2D14-4030
Explanation: Configuration error, incorrect multipath connection. Use MAP3144 to determine resolution.
Response:
2D14-4040
Explanation: Configuration error, incomplete multipath connection between controller and enclosure detected. Use
MAP3144 to determine resolution.
Response:
2D14-4041
Explanation: Configuration error, incomplete multipath connection between enclosure and device detected. Use
MAP3146 to determine resolution.
Response:
2D14-4050
Explanation: Attached enclosure does not support required multipath function. Use MAP3148 to determine
resolution.
Response:
2D14-4060
Explanation: Multipath redundancy level got worse. Use MAP3153 to determine resolution.
Response:
2D14-4100
Explanation: Device bus fabric error. Use MAP3152 to determine resolution.
Response:
421